Menu
SwimLine UVEO

SwimLine UVEO

Hanovia’s SwimLine UVEO UV systems are designed and optimised to deliver effective treatment (chloramine removal and disinfection) for all leisure facilities from spas through to large competition pools. The Swimline UVEO delivers:

  • Single lamp technology delivering high treatment capacity (4 log cryptosporidium reduction at 330m3/hour flow rate)

  • Effective break down of not only monochloramine but also di- and trichloramine which are responsible for eye and skin irritation, headaches and unpleasant odours.

  • 30 – 100% Step-less power control providing enhanced operation flexibility and energy savings

  • UVGuard and UV Shield unique safety features ensures maximum operator protection

Key Features What it gives you benefits for you
INTELLIGENCE
UV sensor Continuous verification of performance with in-built low intensity alarm Easy to monitor and log system performance
Flow and UV transmittance (UVT) meter inputs Stepless adjustment of lamp power based on real time operating conditions Optimised use of energy, saving operating costs
OPTIMISATION
Single medium pressure lamp Provides UV light at 200 to 400 nm wavelengths ideal for the destruction of mono-, di- and trichloramine Visibly clear water with reduced odours
Reduced corrosion risk
Minimises bathers’ eye and skin irritation
Provides germicidal wavelengths to disinfect the water Protect bathers from chlorine resistant microorganisms such as Cryptosporidium or Giardia
Lower maintainance cost compared to multi-lamp system Reduced operating costs
Automatic wiper (quartz cleaning) Self cleaning
INTEGRATION
Designed specifically for pools UVShieldTM power cut-out for lamp access (option) Enhanced operator safety when changing a lamp
Water leak detection (option) Increased bather safety when used with a strainer
RS 485 Modbus Easy integration to building management systems
UV CHAMBER
Material: StSt 316L / 1.4404
Internal finish: As made pipe and tube, welds as laid, electropolished and passivated
External finish: BS EN 10088-2 or 10088-3, 1J or 2J and ASTM No. 4
Process (mating) connections: Flange EN 1092-1 PN16
Drain connection: BSPT
End plate: Removable end plate
Degree of protection: IP65 equivalent to NEMA 4 but not for outside use
Wiper: Automatic (electrically driven)
Arc tube (lamp): Medium pressure
Arc tube enclosure: Pure quartz
Number of arc tubes (lamps): 1
Expected lamp life: 9000 hours
Temperature sensor: Yes
UV sensor: Calibrated DVGW compliant dry sensor with UVGuardTM sensor window
Working fluid temperature: 0°C to 60°C
Strainer: Yes
Hydrostatically pressure tested: Yes to PED requirements EN 13445
Chamber mounting: Horizontal only
Operating pressure: 6 bar
Seals: EPDM, DVGW-W270 D1 and D2, NSF 51 and 61 approved
BALLAST
Enclosure material: Plastic and anodised aluminium
Degree of protection: IP54
Supply voltages: Fed from control cabinet
Operating temperature range: 5°C to 45°C
Relative humidity: <95% non-condensing
Cooling fan: Yes
Interconnecting cable lengths: 2 m to ballast 10 m to chamber
Power adjustment: Stepless variable power (30 to 100% of maximum ballast rating)
APPROVALS
CE marked
CABINET
Material: Polyester coated carbon steel
Degree of protection: IP66 / NEMA 4
Supply voltages: 380 V to 480 V ±10% 50/60 Hz (2 ph L1, L2)
Operating temperature range: 5°C to 40°C
Relative humidity: <95% non-condensing
Cooling fans: No
Interconnecting cable lengths: 2 m to ballast 10 m to chamber
CUSTOMER INPUTS
4-20 mA passive inputs: Flow meter and transmittance meter
VFC inputs: Remote stop/start, Remote reset, Reduce power
24 V dc pulsed inputs: Start and stop
CUSTOMER OUTPUTS
4-20 mA passive outputs: UV intensity, UV dose and chamber temperature
VFC outputs: Lamp ready (enable flow), System running, Common warning, Common trip, Low UV warning, Water leak detected, System in remote
CUSTOMER COMMUNICATIONS PORT
RS 485: Modbus
OPTIONS
Operation and Maintenance manual and printed Installation and Commissioning manual in Chinese, English, French, German and Spanish
Flange options: ANSI 150 (NPT drain), JIS and Table ‘E’
Lead length: 2, 10, 20 and 29 m
Skid mounting
Vent valve
UVShieldTM: Power cut-out for lamp access
Water leak detection
In field UV reference sensor kit