Hanovia’s PureLine UVEO H UV systems are optimised to deliver effective UV disinfection for product and process waters used in the food and beverage industry where sanitary design is required. By using the UVEO H you get:

  • An innovative single medium pressure lamp chamber design

  • Intelligent control technology to automatically deliver optimum disinfection performance with high operational efficiency.

  • The UV dose being produced will eliminate harmful microorganisms, reduce the bio-burden, protect against bio-fouling

  • A reduced CIP / SIP frequency and lower operating costs.

  • The intuitive control system will monitor external flow and transmittance meter inputs and ensure optimum UV system performance based on real time operating conditions.

Key Features What it gives you benefits for you
INTELLIGENCE
UV sensor Continuous verification of performance with in-built low UV dose alarm Easy to monitor and log system performance
UVGuard™ on UV sensor window Protects against UV exposure when checking a UV duty sensor with a reference sensor while the system is operating Ability to safely audit the UV performance without interrupting production
Flow and UV transmittance (UVT) meter inputs Stepless adjustment of lamp power based on real time operating conditions Optimised use of energy, saving operating costs
OPTIMISATION
Single medium pressure lamp Provides germicidal wavelengths to disinfect your product or process water Does not affect taste and colour of final product
No chemicals
Protects pre-treatment equipment and RO filters from bio-fouling reducing CIP frequency and downtime
High treatment capacity with a single lamp Compact footprint and reduced operating cost
Innovative chamber design Maximises the water’s exposure to UV light Reduces energy costs
Designed specifically for the food and beverage industry where sanitary design is required Chamber has tri-clamp connections, <0.8 μm internal finish electropolished and passivated Industry compliance, reduced risk of microbiological contamination
FDA and EC approved seals
*Automatic wiper Self cleaning to maintain performance
 INTEGRATION
Designed for your process *Skid mountable Easy to install
*UVShield™ power cut-out for lamp access Enhanced operator safety when changing a lamp
*Water leak detection Increased product safety
RS 485 Modbus Easy integration to SCADA or plant control systems
*Option
UV CHAMBER
Material: StSt 316L / 1.4404
Internal finish: Tube, welds as laid, <0.8 μm Ra electropolished and passivated
External finish: BS EN 10088-2 or 10088-3, 1J or 2J and ASTM No. 4
Process (mating) connections: Tri-clamp DIN 32676 SER A
Drain connection: Tri-clamp blanked off
End plate: Removable end plate
Degree of electrical protection: IP65 equivalent to NEMA 4 but not for outside use
Arc tube (lamp): Medium pressure
Arc tube enclosure: Pure quartz
Number of arc tubes (lamps): 1
Expected lamp life: 9000 hours
Temperature sensor: Yes
UV sensor: Calibrated DVGW compliant dry sensor with UVGuard™ sensor window
Working fluid temperature: 0°C to 60°C (80°C unwiped)
Maximum CIP temperature: 95°C lamp off and CIP request acknowledged
Hydrostatically pressure tested: Yes to PED requirements EN 13445
Chamber mounting: Horizontal only
Operating pressure: 10 bar
Seals: EPDM, ADI free, EC 1935/2004, FDA 21 CFR 177.2600 approved
OPTIONS
Document Support Pack
Control cabinet material: Stainless steel 304 or 316 with sloping roof
Operation and Maintenance manual and printed Installation and Commissioning manual in
Chinese, English, French, German and Spanish
Wiper: Automatic (electrically driven)
Flange options: ANSI 150, EN 1092-1 PN16, JIS, Table ‘E’
Chamber internal finish: <0.6 μm Ra or <0.38 μm Ra welds polished out, electropolished and passivated
Lead length: 2, 10, 20 and 29 m
Maximum CIP temperature: 130°C lamp turned off and CIP request acknowledged
Welder Document Pack for chamber construction
Bleed valve: Hygienic valve with tri-clamp connection
Skid mounting
Vent valve: Manual valve hygienic design
Cabinet IP rating: Carbon steel air to air heat exchangers IP 65, NEMA 4 or stainless steel version IP 65, NEMA 4X
OPTIONS (continued)
UVShield™: Power cut-out for lamp access
Water leak detection: Detects water leaking from the UV lamp enclosure
Arc tube enclosure: Doped quartz
In field UV reference sensor kit
CABINET
Material: Polyester coated carbon steel
Degree of protection: IP66 / NEMA 4
Supply voltages: 380 V to 480 V ±10% 50/60 Hz (2 ph L1, L2)
Operating temperature range: 5°C to 45°C
Relative humidity: <95% non-condensing
Cooling fans: No
Interconnecting cable lengths: 2 m to ballast 10 m to chamber
CUSTOMER OUTPUTS
4-20 mA passive outputs: UV RED dose, UV average dose, UV intensity and chamber temperature
VFC outputs: Lamp ready (enable flow), system running, common warning, common trip, low dose warning, water leak detected, system in remote, OK to CIP
CUSTOMER INPUTS
4-20 mA active or passive inputs: Flow meter and transmittance meter
VFC inputs: Remote stop/start, remote reset, remote CIP request, reduce power
24 V dc pulsed inputs: Start and stop
CUSTOMER COMMUNICATIONS PORT
BALLAST
Enclosure material: Plastic and anodised aluminium
Degree of protection: IP54
Supply voltages: Fed from control cabinet
Operating temperature range: 5°C to 45°C
Relative humidity: <95% non-condensing
Cooling fans: Yes
Interconnecting cable lengths: 2 m to ballast 10 m to chamber
Power adjustment: Stepless variable power (30 to 100% of maximum ballast rating)
APPROVALS
CE marked

Coming Soon