PureLine D

Medium Pressure – 10 to 470m3/hour flow rate

Low Pressure – 2 to 100m3/hour flow rate

Hanovia's PureLine D systems are aimed specifically at providing UV disinfection for product and process waters used in the food and beverage industry. By using a UV system you will disinfect the water, eliminate harmful micro-organisms, reduce the bio-burden, protect against bio-fouling, lead to fewer CIP/SIP cycles and lower operating costs. Each system comes with a UV monitor to measure the germicidal output of the UV system and make it easy to monitor and log performance.

Key Features What it gives you benefits for you
INTELLIGENCE
UV intensity monitor measuring germicidal wavelengths Continuous verification of performance with in-built low intensity alarm Easy to monitor and log system performance
OPTIMISATION
UV water disinfection Protect your process waters from microbiological contamination including chlorine resistant Cryptosporidium and Giardia Does not affect taste and colour of final product
No chemicals
Designed for the food and beverage industry FDA-approved materials used for all wetted parts Industry compliant materials
*Chamber with tri-clamp connections and <0.38 μm internal finish Sanitary design
*Automatic wiper (quartz cleaning) Self cleaning
INTEGRATION
Compact design Can be fitted to skids Easy integration
Can be retrofitted to existing process
*Option
UV CHAMBER
Material: Stainless steel 316L / 1.4404
Internal finish: As made pipe and tube, welds as laid, electropolished and passivated
External finish: Sateen polish (120 grit) electropolished and passivated
Process (mating) connections: Flange EN 1092-1 PN16
Drain connection: Tri-clamp to ISO 2037
End plate: Removable end plate
Degree of protection: IP65 equivalent to NEMA 4 but not for outside use
Arc tube (lamp): Medium pressure
Arc tube enclosure: Pure quartz
Number of arc tubes (lamps): 1 (D 0070-0300), 4 (D 0350-0550), 6 (D 0900), 8 (D 0950)
Expected lamp life: 8000 hours, 4000 hours D 0240 and 0300
Temperature sensor: Yes
UV monitor: Wet UV monitor (if above minimum T10)
Working fluid temperature: 5°C to 60°C (80°C unwiped)
Maximum CIP temperature: 95°C with cabinet electrically isolated
Hydrostatically pressure tested: Yes to PED requirements EN 13445
Chamber mounting: Horizontal only
Operating pressure: 6 bar
Seals: EPDM, ADI free, EC 1935/2004, FDA 21 CFR 177.2600 approved
OPTIONS
Document Support Pack
Cabinet material: Stainless steel 316
Operation and Maintenance manual and printed Installation and Commissioning manual in
Chinese, English, French, German and Spanish
Wiper: automatic (electrically driven)
Flange options: ANSI 150, JIS, Table ‘E’ and tri-clamp
Chamber internal finish: <0.38 μm welds polished out, electropolished and passivated
Lead length: 20 m, 30 m or 50 m cabinet to chamber
Maximum CIP temperature: 130°C (panel electrically isolated)
Welder Document Pack for chamber construction
Bleed valve: Hygienic valve with tri-clamp connection
OPTIONS (continued)
Skid mounting
Operating pressure: 10 bar
Power adjustment: 4 level power switching
Vent valve: Manual valve hygienic design
Cabinet IP rating: Carbon steel air to air heat exchangers IP 65, NEMA 4 or stainless steel version IP 65, NEMA 4X
Aggressive water package: For 400 ppm to 20000 ppm chloride water
UVShield™: Power cut-out for lamp access
Water leak detection: Detects water leaks from quartz sleeve.
Arc tube enclosure: Doped quartz
CABINET
Material: Polyester coated carbon steel
Degree of protection: IP54 NEMA 12
Supply voltages (nominal): D 0070-0083 95 V to 260 V
D 0100-0300 190 V to 480 V
D 0350-0950 380 V to 480 V 50/60 Hz
(voltage tolerance ± 10% of nominal)
Operating temperature range: 5°C to 40°C
Relative humidity: <95% non-condensing
Cooling fans: Yes
Interconnecting cable lengths: 10 m cabinet to chamber
CUSTOMER OUTPUTS
4-20 mA passive or active output: UV intensity %
VFC outputs: System warning, lamp ready, low UV intensity, common
trip, remote reset, ELCB or water leak, system available,
local or remote mode
CUSTOMER INPUTS
4-20 mA passive or active input: Flow meter
VFC inputs: Remote stop/start and remote reset
CUSTOMER COMMUNICATIONS PORT
None
APPROVALS
CE marked
UV CHAMBER
Material: StSt 316L / 1.4404
Internal finish: As made pipe and tube, welds as laid, electropolished and passivated
External finish: Sateen polish (120 grit) electropolished and passivated
Process (mating) connections: Flange EN 1092-1 PN16
Drain connection: Tri-clamp to ISO 2037
End plate: Removable tri-clamp except D 0089 which is flanged
Degree of protection: IP65 equivalent to NEMA 4 but not for outside use
Arc tube (lamp): Low pressure amalgam
Arc tube enclosure: Pure quartz
Number of arc tubes (lamps): 1
Expected lamp life: 12000 hours
Temperature sensor: On D 0089 only
UV monitor: Wet UV monitor (if above minimum T10)
Working fluid temperature: 5°C to 40°C
Maximum CIP temperature: 95°C with cabinet electrically isolated
Hydrostatically pressure tested: Yes to PED requirements EN 13445
Chamber mounting: Horizontal or vertical except D 0089 which is horizontal only
Operating pressure: 10 bar
Seals: EPDM, ADI free, EC 1935/2004, FDA 21 CFR 177.2600 approved
OPTIONS
Document Support Pack
Cabinet material: Stainless steel 304 or 316 with sloping roof
Operation and Maintenance manual and printed Installation and Commissioning manual in
Chinese, English, French, German and Spanish
Wiper: Automatic (pneumatically driven) except D 0003
Flange options: ANSI 150, JIS, Table ‘E’ and tri-clamp
Chamber internal finish: Tri-clamp chamber only <0.38 μm, welds left as laid, electropolished and passivated
Maximum CIP temperature: 130°C (panel switched off)
Welder Document Pack for chamber construction
Skid mounting
CABINET
Material: Polyester coated carbon steel
Degree of protection: IP65 / NEMA 4 except D 0089 which is IP54 NEMA 12
Supply voltages: 230 V (207 V to 253 V) 50/60 Hz
Operating temperature range: 5°C to 40°C
Relative humidity: <95% non-condensing
Cooling fans: D 0089 only
Interconnecting cable lengths: 5 m
CUSTOMER OUTPUTS
4-20 mA passive outputs: UV intensity %
VFC outputs: Lamp ON and Low UV warning
CUSTOMER INPUTS
VFC inputs: Remote stop/start and remote reset
CUSTOMER COMMUNICATIONS PORT
None
APPROVALS