PharmaLine DP

PharmaLine DP

Hanovia’s PharmaLine DP systems are aimed specifically at providing UV disinfection for Purified Water Generation System Pre-treatment where sanitary design is not critical. By using a UV system you will disinfect the water, eliminate objectionable organisms, reduce the bio-burden, protect against bio-fouling, lead to fewer CIP/SIP cycles and lower operating costs. Each system comes with a UV monitor to measure the germicidal output of the UV system and make it easy to monitor and log performance. The systems all use low pressure amalgam lamps providing energy efficient germicidal wavelength and long lamp life to reduce operating costs.

Key Features What it gives you benefits for you
INTELLIGENCE
UV intensity monitor measuring germicidal wavelengths Continuous verification of performance with in-built low intensity alarm Easy to monitor and log system performance
OPTIMISATION
Single low pressure amalgam lamp technology (LPHO) Targeted microbiological wavelength Proven log reduction of microorganisms as part of a multi-barrier purified water process
Reduced bio-burden in pre-treatment equipment, leading to fewer CIP / SIP cycles and optimised production efficiency
Protects RO membranes from bio-fouling, reducing CIP frequency and downtime
Designed for pre-treatment processes in the pharmaceutical industry Flanged connections, standard internal finish Reduced system costs where sanitary design is not critical
FDA-approved materials used for all wetted parts Industry compliant materials
Option of sanitary design for the pharmaceutical industry based on cGMP principles Sanitary design with industry compliance; reduced risk of microbiological contamination; enhances control of your process as part of a multibarrier system
INTEGRATION
Compact design Can be fitted to skids Easy integration
Can be retrofitted to existing process
UV CHAMBER
Material: StSt 316L / 1.4404
Internal finish: As made pipe and tube, welds as laid, electropolished and passivated
External finish: Sateen polish (120 grit) electropolished and passivated
Process (mating) connections: Flange EN 1092-1 PN16
Drain connection: Tri-clamp to ISO 2852
End plate: Removable tri-clamp except DP 0089 which is flanged
Degree of protection: IP65 equivalent to NEMA 4 but not for outside use
Arc tube (lamp): Low pressure amalgam
Arc tube enclosure: Pure quartz
Number of arc tubes (lamps): 1
Expected lamp life: 12000 hours
Temperature sensor: On DP 0089 only
UV monitor: Wet UV monitor
Working fluid temperature: 5°C to 40°C
Maximum CIP temperature: 95°C with cabinet electrically isolated
Hydrostatically pressure tested: Yes to PED requirements EN 13445
Chamber mounting: Horizontal or vertical except DP 0089 which is horizontal only
Operating pressure: 10 bar
Seals: EPDM, FDA 21 CFR 177.2600, USP Class VI 121°C approved
OPTIONS
Document Support Pack
Cabinet material: Stainless steel 304
Operation and Maintenance manual and printed Installation and Commissioning manual in Chinese, English, French, German and Spanish
Wiper: automatic (pneumatically driven) except DP 0003
Flange options: ANSI 150, JIS, Table ‘E’ and tri-clamp with chamber internal finish
Maximum CIP temperature: 130°C (panel switched off)
Welder Document Pack for chamber construction
Skid mounting
CABINET
Material: Polyester coated carbon steel
Degree of protection: IP65 / NEMA 4 except DP 0089 which is IP54 NEMA 12
Supply voltages: 230 V (207 V to 253 V) 50/60 Hz
Operating temperature range: 5°C to 40°C
Relative humidity: <95% non-condensing
Cooling fans: DP 0089 only
Interconnecting cable lengths: 5 m
CUSTOMER OUTPUTS
4-20 mA passive output: UV intensity %
VFC outputs: Lamp ON and Low UV warning
CUSTOMER INPUTS
VFC inputs: Remote stop/start and remote reset
CUSTOMER COMMUNICATIONS PORT
None
APPROVALS
CE marked

Coming Soon

Connect With Us