Menu
PharmaLine DO

PharmaLine DO

Low Pressure

Hanovia’s PharmaLine DO UV systems are designed based on cGMP principles specifically for providing ozone destruction for pharmaceutical purified water distribution loops where sanitary design is critical. When installed in a distribution loop the PharmaLine DO will

  • remove residual ozone dosed into the water to maintain microbiological integrity before the points of use

  • interlock with the distribution control system to switch off and on during a planned sanitisation procedure

  • Measure UV lamp intensity using a wet UV monitor to make it easy for the operator to assess and log performance.

Key Features What it gives you benefits for you
INTELLIGENCE
UV intensity monitor / sensor measuring UV wavelengths Continuous verification of performance with in-built low intensity alarm Easy to monitor and log system performance
OPTIMISATION
Single lamp technology Optimised for ozone reduction Proven log reduction of ozone
Lower power use than comparable multi-lamp systems Lower operating costs
Lower maintenance cost compared to multi-lamp systems
Designed for the pharmaceutical industry based on cGMP principles Sanitary design with <0.38 μm internal surface finish and tri-clamp connections as standard Industry compliance; reduced risk of microbiological contamination; enhances control of your process as part of a multibarrier system
FDA-approved materials used for all wetted parts
Remote control function Matches automated SIP ozonation procedure
INTEGRATION
Compact design Can be fitted to skids Easy integration
Can be retrofitted to existing process
UV CHAMBER
Material: StSt 316L / 1.4404
Internal finish: <0.38 μm Ra welds polished out, electropolished and passivated
External finish: Sateen polish (120 grit) electropolished and passivated
Process (mating) connections: Tri-clamp to ISO 2852
Drain connection: Tri-clamp to ISO 2852
End plate: Removable tri-clamp
Degree of protection: IP65 equivalent to NEMA 4 but not for outside use
Arc tube (lamp): Low pressure amalgam
Arc tube enclosure: Pure quartz
Number of arc tubes (lamps): 1
Expected lamp life: 12000 hours
Temperature sensor: On DO 0020 only
UV monitor: Wet UV monitor
Working fluid temperature: 5°C to 40°C
Maximum CIP temperature: 95°C with cabinet electrically isolated
Hydrostatically pressure tested: Yes to PED requirements EN 13445
Chamber mounting: Horizontal or vertical except DO 0020 which is horizontal only
Operating pressure: 10 bar
OPTIONS
Document Support Pack
Cabinet material: Stainless steel 304
Operation and Maintenance manual and printed Installation and Commissioning manual in Chinese, English, French, German and Spanish
Maximum CIP temperature: 130°C (panel switched off)
Welder Document Pack for chamber construction
Skid mounting
CABINET
Material: Polyester coated carbon steel
Degree of protection: IP65 / NEMA 4 except DO 0020 which is IP54 NEMA 12
Supply voltages: 230 V (207 V to 253 V) 50/60 Hz
Operating temperature range: 5°C to 40°C
Relative humidity: <95% non-condensing
Cooling fans: DO 0020 only
Interconnecting cable lengths: 5 m
CUSTOMER OUTPUTS
4-20 mA passive outputs: UV intensity %
VFC outputs: Lamp ON and Low UV warning
CUSTOMER INPUTS
VFC inputs: Remote stop/start and remote reset
CUSTOMER COMMUNICATIONS PORT
None
APPROVALS
CE marked

Coming Soon

Connect With Us